RPS-400 series

400W Reliable Green Medical Power Supply

RPS-400 is a 400W highly reliable green PCB type medical power supply with a high power density on the 5” by 3” footprint. It accepts 80~264VAC input and offers various output voltages between 12V and 48V.

These models has a Enclosed type , Enclosed type with fan on top , Enclosed type with fan on the side – contact us for this special feature

Choose your option:

Description

RPS-400 series

400W Reliable Green Medical Power Supply

RPS-400 is a 400W highly reliable green PCB type medical power supply with a high power density on the 5” by 3” footprint. It accepts 80~264VAC input and offers various output voltages between 12V and 48V. The working efficiency is up to 94% and the extremely low no load power consumption is down below 0.5W. RPS-400 (blank type only) is able to be used for both ClassⅠ(with FG) and ClassⅡ(no FG) system design. The extremely low leakage current is less than 160μA. In addition, it conforms to the international medical regulations (2*MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF rated “patient contact” medical system equipment.

Features (RPS-400) :

  • 5″x 3″ compact size
  • Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1 and IEC/BS EN/EN60601-1
  • Suitable for BF application with appropriate system consideration
  • 250W convention, 400W force air
  • EMI Conduction for Class B Radiation for Class B with FG(ClassⅠ) and Class A without FG(ClassⅡ)
  • No load power consumption<0.5W
  • Extremely low leakage current
  • 12V/0.5A fan supply
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Operating altitude up to 4000 meters

Applications :

  • Oral irrigator
  • Hemodialysis machine
  • Medical monitors
  • Sleep apnea devices
  • Pumps machine
  • Electric bed

Additional information

Weight 15 kg
Dimensions 12.7 × 7.62 × 3.5 cm
RPS-400 Types :

RPS-400-12, RPS-400-15, RPS-400-18, RPS-400-24, RPS-400-27, RPS-400-36, RPS-400-48, RPS-400-12-C, RPS-400-15-C, RPS-400-18-C, RPS-400-24-C, RPS-400-27-C, RPS-400-36-C, RPS-400-48-C, RPS-400-12-TF, RPS-400-15-TF, RPS-400-18-TF, RPS-400-24-TF, RPS-400-27-TF, RPS-400-36-TF, RPS-400-48-TF, RPS-400-12-SF, RPS-400-15-SF, RPS-400-18-SF, RPS-400-24-SF, RPS-400-27-SF, RPS-400-36-SF, RPS-400-48-SF

Specifications

Model RPS-400-12 RPS-400-15 RPS-400-18 RPS-400-24 RPS-400-27 RPS-400-36 RPS-400-48
Output DC VOLTAGE 12V 15V 18V 24V 27V 36V 48V
CURRENT Convection 0 ~ 33.3A 0 ~ 26.7A 0 ~ 22.3A 0 ~ 16.7A 0 ~ 14.9A 0 ~ 11.2A 0 ~ 8.4A
20.5CFM 0 ~ 20.8A 0 ~ 16.7A 0 ~ 13.9A 0 ~ 10.5A 0 ~ 9.3A 0 ~ 7A 0 ~ 5.3A
RATED POWER Convection 399.6W 400.5W 401.4W 400.8W 402.3W 403.2W 403.2W
20.5CFM 249.6W 250.5W 250.2W 252W 251.1W 252W 254.4W
RIPPLE & NOISE (max.) 120mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p
VOLTAGE TOLERANCE ±3.0% ±3.0% ±3.0% ±2.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load
Input VOLTAGE RANGE 80 ~ 264VAC 113 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR PF>0.94/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.) 91.5% 92% 93% 93% 93.5% 94% 94%
AC CURRENT (Typ.) 4.2A/115VAC 2.1A/230VAC
INRUSH CURRENT (Typ.) COLD START 35A/115VAC 70A/230VAC
LEAKAGE CURRENT Earth leakage current <200 A/264VAC 50Hz , Touch current < 70 A/264VAC