HSP-300 Series

300W Single Output with PFC Function

Features :

  • Universal AC input / Full range.
  • Withstand 300 VAC surge input for 5 seconds.
  • Built-in active PFC function.
  • Low leakage current < 1.0mA
  • Protections : short circuit / Overload / Over voltage / Over temperature.
  • Cooling by free air convection
  • Low profile : 31mm.
  • Conformal coated.
  • LED indicator.
  • Suitable for high efficacy moving sign applications.


These models has a redundant option
– contact us for this special feature

Choose your option:

Description

HSP-300 Series

300W Single Output with PFC Function

Features :

  • Universal AC input / Full range.
  • Withstand 300 VAC surge input for 5 seconds.
  • Built-in active PFC function.
  • Low leakage current < 1.0mA
  • Protections : short circuit / Overload / Over voltage / Over temperature.
  • Cooling by free air convection
  • Low profile : 31mm.
  • Conformal coated.
  • LED indicator.
  • Suitable for high efficacy moving sign applications.

Installation :

1.Operate with additional aluminum plate  :

In order to meet the“Derating Curve”and the “Static Characteristics” ,HSP-300 series must be installed onto an aluminum plate(or the cabinet of the same size) on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and smooth surface (or coated with thermal grease), and HSP-300 series must be firmly mounted at the center of the aluminum plate.

2.For heat dissipation :

At least 5cm installation distance around the PSU should be kept.

Additional information

Weight 12.1 kg
Dimensions 21 × 8.1 × 3.1 cm
HSP-300 Types :

HSP-300-2.8, HSP-300-4.2, HSP-300-5

Specifications

Model HSP-300-2.8 HSP-300-4.2 HSP-300-5
Output DC VOLTAGE 2.8V 4.2V 5V
RATED CURRENT 60A 60A 60A
CURRENT RANGE 0 ~ 60A 0 ~ 60A 0 ~ 60A
RATED POWER 168W 252W 300W
RIPPLE & NOISE (max.) 110mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE 2.5~3V 3.6~4.4V 4.5~5.5V
VOLTAGE TOLERANCE ±2.0% ±2.0% ±2.0%
LINE REGULATION ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 2000ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load
HOLD UP TIME (Typ.) 8ms/230VAC 8ms/115VAC at full load
Input VOLTAGE RANGE 180 ~ 264VAC 254 ~ 370VDC or 90~135VAC 127~190VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF≥0.93/230VAC PF ≥0.98/115VAC at full load
EFFICIENCY (Typ.) 80% 85% 87%
AC CURRENT (Typ.) 2.8A/115VAC 1.4A/230VAC 3.9A/115VAC 1.95A/230VAC 4.7A/115VAC 2.35A/230VAC
INRUSH CURRENT (Typ.) Cold start 30A/115VAC 60A/230VAC
LEAKAGE CURRENT ‘<‘1mA / 240VAC