RPS-60 series

60W Reliable Green Medical Power Supply

RPS-60 is a 60W highly reliable green PCB type medical power supply with a high power density on the 4” by 2” footprint. It accepts 80~264VAC input and offers various output voltages between 3.3V and 48V.

Choose your option:

Description

RPS-60 series

60W Reliable Green Medical Power Supply

RPS-60 is a 60W highly reliable green PCB type medical power supply with a high power density on the 4” by 2” footprint. It accepts 80~264VAC input and offers various output voltages between 3.3V and 48V.

The working efficiency is up to 86% and the extremely low no load power consumption is down below 0.75W. RPS-60 is able to be used for ClassⅡ(no FG) system design. The extremely low leakage current is less than 130μA. In addition, it conforms to international medical regulations (2*MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF rated “patient contact” medical system equipment.

Features (RPS-60) :

  • 4″x2″ compact size
  • Medical safety approved (2 x MOPP) according to
  • ANSI/AAMI ES60601-1 and IEC/BS EN/EN60601-1
  • Suitable for BF application with appropriate system consideration
  • Cooling by free air convection
  • EMI class B for class Ⅱ configuration
  • No load power consumption<0.75W
  • Extremely low leakage current
  • Protections: Short circuit / Overload / Over voltage
  • Operating altitude up to 3000 meters

Applications :

  • Oral irrigator
  • Hemodialysis machine
  • Medical computer monitors
  • Sleep apnea devices

Additional information

Weight 15.4 kg
Dimensions 10.16 × 5.08 × 2.9 cm
RPS-60 Types :

RPS-60-3.3, RPS-60-5, RPS-60-12, RPS-60-15, RPS-60-24, RPS-60-48

Specifications

Model RPS-60-3.3 RPS-60-5 RPS-60-12 RPS-60-15 RPS-60-24 RPS-60-48
Output DC VOLTAGE 3.3V 5V 12V 15V 24V 48V
RATED CURRENT 10A 10A 5A 4A 2.5A 1.25A
CURRENT RANGE 0 ~ 11A 0 ~ 11A 0 ~ 5.5A 0 ~ 4.4A 0 ~ 2.75A 0 ~ 1.375A
RATED POWER 33W 50W 60W 60W 60W 60W
PEAK LOAD(10sec.) 36.3W 55W 66W 66W 66W 66W
RIPPLE & NOISE (max.) 60mVp-p 60mVp-p 60mVp-p 100mVp-p 100mVp-p 100mVp-p
VOLTAGE TOLERANCE ±2.0% ±2.0% ±2.0% ±2.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 60ms/230VAC 12ms/115VAC at full load
Input VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 74% 79% 84% 85% 87% 86%
AC CURRENT (Typ.) 1.8A/115VAC 1 A/230VAC
INRUSH CURRENT (Typ.) COLD START 60A/230VAC 30A/115VAC
LEAKAGE CURRENT Earth leakage current < 130 A/264VAC , Touch current < 100 A/264VAC