PLD-40 series

40W Single Output LED Power Supply

The Mean Well PLD-40 Series LED driver is a 40W Single Output Constant Current LED power supply. The PLD-40’s Series have built-in active PFC function, protections including short circuit and over temperature. Fully isolated in a plastic case with strain relief design the unit is IP30 rated and is suitable for LED lighting applications.

Choose your option:

Description

PLD-40 series

40W Single Output LED Power Supply

The Mean Well PLD-40 Series LED driver is a 40W Single Output Constant Current LED power supply. The PLD-40’s Series have built-in active PFC function, protections including short circuit and over temperature. Fully isolated in a plastic case with strain relief design the unit is IP30 rated and is suitable for LED lighting applications.

Features (PLD-16) :

  • Built in active PFC function
  • Protections for Short Circuit and Over Temperature
  • Cooling by free air convection
  • Fully isolated plastic case
  • Class 2 Power Unit
  • IP30 Design
  • Suitable for indoor LED lighting applications
  • 100% full burn in test
  • Low cost
  • High reliability

Additional information

Weight 7.3 kg
Dimensions 12.8 × 6.0 × 3.15 cm
PLD-40 Types :

PLD-40-350B, PLD-40-500B, PLD-40-700B, PLD-40-1050B, PLD-40-1400B, PLD-40-1750B

Specifications

Model PLD-40-350B PLD-40-500B PLD-40-700B PLD-40-1050B PLD-40-1400B PLD-40-1750B
Output RATED CURRENT 350mA 500mA 700mA 1050mA 1400mA 1750mA
OPERATING VOLTAGE RANGE 70 ~ 108V 45 ~ 80V 34 ~ 57V 22 ~ 38V 17 ~ 29V 13 ~ 23V
CURRENT ACCURACY ±5.0%
RATED POWER 37.8W 40W 39.9W 39.9W 40.6W 40.25W
RIPPLE & NOISE (max.) 9.5Vp-p 5.0Vp-p 3.1Vp-p 2.6Vp-p 2.5Vp-p 2.4Vp-p
NO LOAD OUTPUT VOLTAGE (max.) 118V 100V 63V 50V 35V 35V
SETUP TIME 500ms / 230VAC at full load
Input VOLTAGE RANGE 180 ~ 295VAC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to “Power Factor Characteristic” curve)
EFFICIENCY (Typ.) 88% 88% 87% 87% 86% 86%
AC CURRENT 0.35A/230VAC 0.3A/277VAC
INRUSH CURRENT(Typ.) COLD START 25A (twidth=60μs measured at 50% Ipeak) at 230VAC
LEAKAGE CURRENT <0.5mA / 240VAC